T SDR 11

T-piece, SDR 11

T-piece T SDR 11

  • Gas, water and H2
  • Maximum pressure: Gas 10 bar, Water 16 bar
  • Material: PE 100
  • Safety technology
  • DVGW test mark: DV-8606AU2249 and DV-8611AU2250
  • FM Approvals Class: 1613 (d 75 - d 315)
Go back Data sheet

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d B D h L L1 t z Weight kg BX PU
612165 75 111 96 37 278 187 62 69 0,980 8 144
612166 90 129 117 44 305 211 71 74 1,650 10 80
612167 110 152 142 48 355 248 79 91 2,580 6 48
612168 125 168 160 44 384 272 79 105 3,520 5 40
615277 160 206 200 41 430 315 88 119 5,820 3 24
615691 180 234 228 62 480 354 95 137 7,900 2 16
616266 200 255 251 54 550 400 109 160 11,130 1 8
615692 225 286 284 63 580 432 111 172 13,900 1 8
616412 250 - 310 80 770 540 128 254 27,400 1 4
616413 280 - 350 84 905 630 139 312 42,200 1 2
616414 315 - 396 80 940 670 150 359 55,900 1 1

For T d75 - d225 straight pass through, can be fused in one step, therefore only 2 fusions in total. For T > d225 separate fusion zones per socket side.

FRIALEN safety fittings can be fused with pipes with SDR levels 11 to 17.6. Other levels of SDR can be processed on request. Please note the mandatory labels directly on the product. DVGW test mark issued: DV-8606AU2249 and DV-8611AU2250.

Areas of Application

The FRIALEN T-pieces are used for equal pipe outlets of HD-PE pipelines.

Assembly Instructions

The fusion of the pipe ends with the FRIALEN T-piece takes place by FRIALEN electrofusion – leakproof and longitudinally strong.

The pipe ends are prepared according to the general installation instructions (see “Assembly Instructions for FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”). This involves removing the oxide skin and cleaning the pipe ends. The FRIALEN-T pieces have a straight passage fusible in one step. Therefore a total of only two fusions are necessary.

Good reasons for using the FRIALEN T-piece:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the underground fitting (Traceability-Coding)