TA RED SDR 11

T-piece with reduced spigot, SDR 11

T-piece TA RED SDR 11 with reduced spigot

  • Gas, water and H2
  • Maximum pressure: Gas 10 bar, Water 16 bar
  • Material: PE 100
  • Reduced spigots
  • Safety technology
  • DVGW test mark: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250
Go back Data sheet

With long outlet spigot

With long outlet spigot

Reference d1 d2 B D h L L1 t t1 z Weight kg BX PU
616417 32 20 62 46 22 116 117 44 42 14 0,110 30 540
616418 40 32 70 55 25 146 148 46 51 28 0,170 20 360
616419 50 32 82 69 28 175 158 55 51 33 0,295 10 180
616420 50 40 82 69 28 175 167 55 55 33 0,315 10 180
616421 63 32 96 84 32 197 173 63 51 36 0,435 10 180
616422 63 40 96 84 32 197 182 63 55 36 0,450 10 180
616423 63 50 96 84 32 197 197 63 60 36 0,490 10 180

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.

Minimum wall thickness s minimum ≥ 3 mm.

Other levels of SDR can be processed on request.

Please note the mandatory labels directly on the product.

DVGW test mark issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250.

Dimension B = Diameter D with contact pin

With standard outlet spigots

With standard outlet spigots

Reference d1 d2 B D h L L1 t t1 z Weight kg BX PU
616675 90 32 126 116 43 280 172 79 44 61 1,050 17 136
616676 90 63 126 116 43 280 191 79 63 61 1,100 15 120
616678 110 63 148 141 48 310 216 82 63 73 1,700 8 64
616679 110 90 148 141 48 310 244 82 79 73 1,850 8 64
616681 160 90 205 203 45 390 305 98 79 97 4,400 4 32
616682 160 110 205 203 45 390 308 98 82 97 4,500 4 32
616683 160 125 205 203 45 390 313 98 87 97 4,600 3 24
617174 180 125 228 223 49,9 495 357 105 87 143 7,050 2 16
2 617176 200 90 250 247 50,3 540 360 112 79 158 8,250 1 8
2 617177 200 110 250 247 50,3 540 370 112 82 158 7,720 1 8
2 617178 200 160 250 247 50,3 540 401 112 98 158 9,750 1 8
1 617180 225 90 281 278 61,2 590 389 120 79 175 11,200 1 8
1 617181 225 110 281 278 61,2 590 399 120 82 175 11,900 1 8
1 617182 225 160 281 278 61,2 590 430 120 98 175 13,050 1 8
616427 250 225 - 310 80 770 440 128 - 254 23,500 1 2
616429 280 225 - 350 84 905 475 139 - 312 35,500 1 2
616431 315 225 - 396 80 940 525 150 - 359 43,500 1 2
1 Available from Q2 / 2024
2 Available from Q3 / 2024

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.

Minimum wall thickness s minimum ≥ 3 mm.

Other levels of SDR can be processed on request.

Please note the mandatory labels directly on the product.

DVGW test mark issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250.

Dimension B = Diameter D with contact pin

Areas of Application

The FRIALEN reduced TA red pieces are used for pipe outlets of HD-PE pipelines.

Assembly Instructions

The fusion of the pipe ends with the FRIALEN TA red takes place by FRIALEN-fusing – leakproof and longitudinally strong.

The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).

Good reasons for using the FRIALEN TA red:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • At dim. up to d1 63, Length of outlet spigot dimensioned for two fusion operations

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the fitting (Traceability-Coding)

Downloads