MR SDR 11

Reducer, SDR 11

Reducer MR, SDR 11

  • Gas, water and H2
  • Maximum pressure: Gas 10 bar, Water 16 bar
  • Material: PE 100
  • Safety technology
  • Large insertion depth for good pipe routing (no holding devices required)
  • DVGW test mark: DV-8601AU2248 and DV-8606AU2249
  • FM Approvals Class: 1613 (d 90/63 - d 110/63 + d 110/90 - d 125/90 + d 160/110 - d 225/160)
Go back Data sheet

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d1 d2 SDR range B D1 D2 L t1 t2 Weight kg BX PU
616824 20 16 11 - 17,6 44 32/28 75 36 36 0,035 70 2240
616452 32 16 11 - 17,6 62 45/28 91 39 34 0,060 80 2560
615386 32 20 11 - 17,6 62 45/32 88 39 30 0,060 80 2560
615502 32 25 11 - 17,6 62 45/38 88 39 33 0,070 70 2240
615387 40 20 11 - 17,6 70 54/32 98 43 30 0,080 60 1920
616751 40 25 11 - 17,6 66 54/38 101 50 40 0,090 120 1280
615388 40 32 11 - 17,6 70 54/45 98 43 39 0,090 50 1600
616752 50 25 11 - 17,6 77 66/38 107 52 39 0,120 130 960
612070 50 32 11 - 17,6 82 68/45 110 49 39 0,140 32 1024
612071 50 40 11 - 17,6 82 68/54 110 49 43 0,140 25 800
615389 63 32 11 - 17,6 96 82/45 125 55 44 0,210 18 576
615390 63 40 11 - 17,6 96 82/54 125 55 43 0,220 16 512
612072 63 50 11 - 17,6 96 82/68 125 55 48 0,230 16 512
616583 75 63 11 - 17,6 110 94/79 143 61 55 0,325 15 270
615391 90 50 11 - 17,6 129 117/68 160 69 49 0,470 15 270
615392 90 63 11 - 17,6 129 117/82 160 69 55 0,510 15 270
616582 90 75 11 - 17,6 127 113/94 159 67 63 0,505 15 270
615393 110 63 11 - 17,6 152 142/82 160 79 55 0,730 10 180
615693 110 90 11 - 17,6 152 140/115 180 79 69 0,900 8 144
615694 125 90 11 - 17,6 166 155/115 200 86 69 0,980 8 144
616510 125 110 11 - 17,6 172 157/137 202 95 70 1,300 16 128
615695 160 110 11 - 17,6 207 201/140 230 98 79 1,990 8 64
616511 180 125 11 - 17,6 230 214/155 275 108 74 2,600 1 60
616356 225 160 11 - 17,6 283 282/203 270 110 98 4,860 1 36

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes, with the exception of dimensions d 125/110 and d 180/125. These can be fused with SDR9 - SDR26 pipes. Other levels of SDR can be processed on request. Please note the mandatory labels directly on the product. DVGW test marks issued: DV-8601AU2248 and DV-8606AU2249

Areas of Application

The FRIALEN Electrofusion Reducer MR is applied for immediate pipe reduction within the pipe system.

Assembly Instructions

Fusing of pipe ends with the FRIALEN Electrofusion Reducers MR takes place by FRIALEN fusion – leakproof and longitudinally strong.

The pipe ends are prepared according to the general installation instructions (note “Assembly Instructions” for FRIALEN Safety Fittings for house connections and distribution pipes (remove oxide layer/clean).

Good reasons for using the FRIALEN Electrofusion Reducers MR:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Fusion indicator for visual fusion control

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the underground fitting (Traceability-Coding)

Downloads