TA RED SDR 11

With standard outlet spigots

T-piece TA RED SDR 11 with reduced spigot

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100
  • Reduced spigots
  • Safety technology
  • DVGW test mark: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250
Go back Data sheet

With standard outlet spigots

Reference d1 d2 SDR range B D h L t t1 z Weight [kg] BX PU
616675 90 32 11 - 17,6 126 116 43 280 79 44 61 1,050 10 80
616676 90 63 11 - 17,6 126 116 43 280 79 63 61 1,100 10 80
616678 110 63 11 - 17,6 148 141 48 310 82 63 73 1,700 8 64
616679 110 90 11 - 17,6 148 141 48 310 82 79 73 1,850 8 64
616681 160 90 11 - 17,6 205 203 45 390 98 79 97 4,400 3 24
616682 160 110 11 - 17,6 205 203 45 390 98 82 97 4,500 3 24
616683 160 125 11 - 17,6 205 203 45 390 98 87 97 4,600 3 24
617174 180 125 11 - 17,6 228 223 49,9 495 105 87 143 7,160 2 16
1 617176 200 90 11 - 17,6 250 247 50,3 540 112 79 158 8,410 1 8
1 617177 200 110 11 - 17,6 250 247 50,3 540 112 82 158 8,890 1 8
1 617178 200 160 11 - 17,6 250 247 50,3 540 112 98 158 9,900 1 8
1 617180 225 90 11 - 17,6 281 278 61,2 590 120 79 175 11,550 1 8
1 617181 225 110 11 - 17,6 281 278 61,2 590 120 82 175 12,200 1 8
1 617182 225 160 11 - 17,6 281 278 61,2 590 120 98 175 13,370 1 8
616427 250 225 11 - 17,6 - 310 80 770 128 - 254 21,800 1 2
616429 280 225 11 - 17,6 - 350 84 905 139 - 312 30,800 1 2
616431 315 225 11 - 17,6 - 396 80 940 150 - 359 43,500 1 2
1 Available from Q2 / 2025

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.

Minimum wall thickness s minimum ≥ 3 mm.

Other levels of SDR can be processed on request.

Please note the mandatory labels directly on the product.

DVGW test mark issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250.

Dimension B = Diameter D with contact pin

Areas of Application

The FRIALEN reduced TA red pieces are used for pipe outlets of HD-PE pipelines.

Assembly Instructions

The fusion of the pipe ends with the FRIALEN TA red takes place by FRIALEN-fusing – leakproof and longitudinally strong.

The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).

Good reasons for using the FRIALEN TA red:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • At dim. up to d1 63, Length of outlet spigot dimensioned for two fusion operations

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the fitting (Traceability-Coding)