Spigot saddle, SDR 11
Spigot saddle SA SDR 11
- Gas, water and H2
- Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
- Material: PE 100-RC
- Saddle component with clamp
- Tapping under pressure possible
- Safety technology
- DVGW test mark: DV-8601AU2248 and DV-8606AU2249.
Note:
For the pressure-free tapping, there is our drilling device FWAB.
For tapping under pressure, we recommend the drilling tool from Hütz & Baumgarten (www.huetz-baumgarten.de).
If required, please contact our hotline: +49 621 486-2325.
PE 100-RC SDR 11
Maximum permissible working pressure 16 bar (water) / 10 bar (gas)
| Reference | d1 | d2 | B1 | B2 | D1 | d3 | h | L | t | Drilling Ø da | Weight [kg] | BX | Pallet quantity |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 612757 | 63 | 32 | 108 | 118 | 63 | 22 | 171 | 100 | 44 | 20 | 0,340 | 20 | 360 |
| 612759 | 63 | 50 | 108 | 118 | 63 | 37 | 184 | 113 | 55 | 36 | 0,370 | 20 | 360 |
| 615020 | 75 | 50 | 110 | 125 | 75 | 38 | 167 | 82 | 55 | 36 | 0,430 | 15 | 270 |
| 615285 | 90 | 32 | 155 | 150 | 90 | 21 | 207 | 103 | 44 | 20 | 0,710 | 20 | 160 |
| 612819 | 90 | 63 | 155 | 150 | 90 | 50 | 207 | 103 | 63 | 46 | 0,740 | 20 | 160 |
| 615334 | 110 | 32 | 178 | 180 | 110 | 24 | 238 | 125 | 51 | 20 | 0,820 | 12 | 96 |
| 615031 | 110 | 50 | 178 | 180 | 110 | 39 | 245 | 132 | 60 | 36 | 0,810 | 12 | 96 |
| 612760 | 110 | 63 | 178 | 180 | 110 | 49 | 263 | 150 | 81 | 46 | 0,860 | 12 | 96 |
| 615411 | 110 | 90 | 165 | 190 | 110 | 70 | 228 | 115 | 79 | 65 | 0,970 | 12 | 96 |
| 615087 | 125 | 32 | 190 | 185 | 125 | 21 | 248 | 109 | 44 | 20 | 0,950 | 12 | 96 |
| 612761 | 125 | 63 | 190 | 185 | 125 | 47 | 248 | 109 | 63 | 46 | 0,990 | 12 | 96 |
| 615412 | 125 | 90 | 185 | 205 | 125 | 70 | 243 | 116 | 79 | 65 | 1,080 | 12 | 96 |
| 615584 | 125 | 110 | 185 | 205 | 125 | 86 | 243 | 116 | 82 | 84 | 1,150 | 10 | 80 |
| 612886 | 160 | 32 | 223 | 265 | 160 | 21 | 289 | 126 | 44 | 20 | 1,440 | 8 | 64 |
| 612762 | 160 | 63 | 223 | 265 | 160 | 47 | 303 | 140 | 63 | 46 | 1,520 | 6 | 48 |
| 615413 | 160 | 90 | 223 | 265 | 160 | 70 | 303 | 140 | 79 | 65 | 1,640 | 2 | 36 |
| 615739 | 160 | 110 | 223 | 265 | 160 | 86 | 303 | 140 | 82 | 84 | 1,770 | 2 | 36 |
| 615585 | 160 | 125 | 223 | 265 | 160 | 98 | 303 | 140 | 87 | 95 | 1,890 | 2 | 36 |
| 612763 | 180 | 63 | 240 | 195 | 180 | 47 | 291 | 109 | 63 | 46 | 1,190 | 6 | 48 |
| 615414 | 180 | 90 | 241 | 285 | 180 | 70 | 312 | 116 | 79 | 65 | 1,820 | 2 | 36 |
| 615948 | 180 | 110 | 241 | 285 | 180 | 86 | 319 | 136 | 82 | 84 | 1,960 | 2 | 36 |
| 615740 | 180 | 125 | 241 | 285 | 180 | 98 | 324 | 141 | 87 | 95 | 2,110 | 2 | 36 |
| 612764 | 200 | 63 | 250 | 195 | 200 | 47 | 311 | 109 | 63 | 46 | 1,180 | 5 | 40 |
| 612765 | 225 | 63 | 255 | 195 | 225 | 47 | 336 | 109 | 63 | 46 | 1,210 | 5 | 40 |
| 615415 | 225 | 90 | 284 | 279 | 225 | 70 | 358 | 130 | 79 | 65 | 1,960 | 5 | 40 |
| 616044 | 225 | 110 | 284 | 279 | 225 | 86 | 368 | 140 | 82 | 84 | 2,080 | 5 | 40 |
| 616045 | 225 | 125 | 284 | 279 | 225 | 97 | 374 | 146 | 87 | 95 | 2,240 | 4 | 32 |
| 616046 | 225 | 160 | 284 | 279 | 225 | 125 | 385 | 157 | 98 | 123 | 2,580 | 4 | 32 |
Areas of Application
The FRIALEN-Spigot Saddles SA are used for tapping into unpressurised gas- and water pipes, as well as in pressure drainage. The connecting pipe is joined to the outlet pipe by using a FRIALEN coupler UB.
FRIALEN safety fittings are fusion-capable with PE pipes according to the specifications of the SDR pipe series on the barcode sticker/datasheet of the respective fitting. The minimum wall thicknesses specified in the standards EN1555-1, EN 12201-1 and ISO 4437 must be observed.
Assembly Instructions
The fusion of the HD-PE distribution line and the HD-PE house connection line with FRIALEN-Spigot Saddles SA is carried out by FRIALEN-fusing – tight and longitudinally force-locking.
The saddle and the outlet are prepared according to the general assembly requirements (see assembly instructions: „FRIALEN safety fittings for sustainable pipes for gas, water networks and industrial systems made of PE“) (remove/clean oxide layer from pipe/spigot).
Tapping in a pressureless state up to Ø 46 mm, from Ø 65 bis Ø 123 mm swarf-reduced using the equipment from Hütz + Baumgarten (www.huetz-baumgarten.de).
For pipes in a non-pressurized state, SA fittings can be used as T-pieces with a reduced outlet.
For information on tapping into the main line under operating pressure, please contact our application engineering department.
Swarfless tapping up to Ø 46 mm, from Ø 65 to Ø 123 mm extremely swarfreduced by using the tapping equipment of Hütz + Baumgarten.
For pipes without pressure spigot saddles SA can be used as a T-piece with a reduced outlet.
For tapping the main line under operating pressure, please contact our Application Engineering Department.
Good reasons for using the FRIALEN-SA:
- Compact construction
- Open wire technology for direct heat transmission
- Preassembled unit without loose parts
- Nearly swarf-less tapping by using Hütz + Baumgarten equipment
- Burr - and nearly ledge - free tapping for a maximum of hydraulic power
- Leak-free drilling possible with shut-off valve
- Extra wide fusion zone
- Additional barcode for tracing back the fitting (Traceability-Coding)