ASFL

Shaft lining adapter for sewage inspection chambers L = 250 mm

Shaft lining adapter for sewage inspection chambers L = 250 mm ASFL

  • Connecting element between a brick shaft or concrete shaft and FRIAFIT sewage insert sleeve AEM for installation on the construction site
  • Reversed anchoring webs (T-section) on the entire circumferential width ensure a firm and tight fit in the shaft
  • Defined internal surface and fitting ratio for reliable system seal with AEM
  • Stable internal diameter due to large wall thickness
Go back Data sheet

PE 100

Maximum permissible test pressure 0.5 bar to DIN EN 1610

Reference d1 Pipe Diameter D L Weight kg BX PU
680505 280 225 250 355 250 4,670 2 16
680507 316 280 400 250 6,650 2 16
680508 357 315 450 250 8,750 1 9
680509 402 355 500 250 11,050 1 6
680511 502 450 630 250 23,400 1 2
680512 628 560 710 250 16,400 1 2
680513 713 630 800 250 20,300 1 2

Sewage pipe systems are high-value assets of a value which has to be maintained for a long time. Increasing demands on the public sewage system require materials which meet these criteria. HDPE sewage pipes have been fused for many years with the FRIAFIT HDPE sewage system tightly, frictionlocked and root-proof.

Areas of Application

The FRIAFIT-Sewage Inspection Chamber Adapter ASF is the joining element between concrete inspection

chamber according to DIN 4034 and the FRIAFIT-Sewage Insert Sleeve AEM.

Assembly Instructions

The ASF is usually fitted in at the concrete works during manufacture of the inspection chambers. Application

of the ASF is possible even on local concrete inspection chambers.

The ASF Sewage Inspection Chamber Adapter is installed according to the general installation requirements (see also “Fitting Instructions” of the FRIAFIT-Sewage System).

Good reasons for using the FRIAFIT-Sewage Inspection Chamber Adapter ASF

  • The ASF is a corrosion resistant HDPE construction part

  • Stable internal diameter due to big wall thickness

  • Anchoring ribs twisted at the rear across the entire width ensure proper and leakfree anchoring in the concrete

  • Width of component and connection HDPE/concrete correspond to DIN 4034

  • Defined internal area for the reliable system sealing (AEM)

  • For subsequent installation in bricks chambers a longer version ASFL (L = 250 mm) was developed

Downloads