Gasket NBR, DIN-EN 682 MOP gas maximum = 5 bar Other water qualities maximum = 16 bar

One-pieced repair clamp for sealing damaged gas and water pipes made of different materials (steel, cast iron, ductile iron, asbestos cement, PVC).

  • Special gasket design for a secure sealing of tapping holes, cracks and corrosion damage
  • Body, closure, bolts and nuts made of stainless steel
  • Gasket material EPDM or NBR
  • Temperature range: -5°C - +40°C
Go back Data sheet

Gasket NBR, DIN-EN 682

MOP gas maximum = 5 bar

Other water qualities maximum = 16 bar

Reference d PN L WS Weight [kg] BX PU
381-044-200 44-48 5 200 17 1,750 10 320
381-048-200 48-52 5 200 17 1,330 10 320
381-048-300 48-52 5 300 17 2,740 10 240
381-054-200 54-58 5 200 17 1,380 10 320
381-054-300 54-58 5 300 17 2,080 10 240
381-060-200 60-67 5 200 17 1,410 10 320
381-060-300 60-67 5 300 17 2,800 10 240
381-070-200 70-77 5 200 17 1,470 9 288
381-075-200 75-83 5 200 17 1,500 9 288
381-075-300 75-83 5 300 17 2,260 9 216
381-082-200 82-89 5 200 17 1,540 9 288
381-082-300 82-89 5 300 17 2,320 9 216
381-087-200 87-95 5 200 17 1,600 9 288
381-087-300 87-95 5 300 17 2,440 9 216
381-088-200 88-98 5 200 17 2,020 8 256
381-095-200 95-104 5 200 17 1,710 6 192
381-095-300 95-104 5 300 17 2,560 6 144
381-108-200 108-118 5 200 17 1,780 6 144
381-108-300 108-118 5 300 17 2,730 6 144
381-108-400 108-118 5 400 17 3,600 6 96
381-113-200 113-123 5 200 17 2,280 5 160
381-113-300 113-123 5 300 17 2,740 5 120
381-113-400 113-123 5 400 17 3,650 5 80
381-120-200 120-131 5 200 17 2,390 5 160
381-132-200 132-142 5 200 19 2,320 4 128
381-132-300 132-142 5 300 19 3,830 4 96
381-135-300 135-145 5 300 19 3,490 4 96
381-139-300 139-149 5 300 19 3,560 4 96
381-159-200 159-170 5 200 19 2,530 3 96
381-159-300 159-170 5 300 19 3,730 3 72
381-159-400 159-170 5 400 19 4,800 3 48
381-167-200 167-178 5 200 19 2,580 3 96
381-167-300 167-178 5 300 19 3,920 3 72
381-167-400 167-178 5 400 19 5,170 3 48
381-215-200 215-225 5 200 19 3,150 1 32
381-215-300 215-225 5 300 19 4,760 1 24
381-215-400 215-225 5 400 19 6,500 1 16
381-269-300 269-280 5 300 19 5,750 1 24
381-320-300 320-330 5 300 19 6,380 1 24

Areas of application

FRIACLAMP repair clamps for secure sealing of damaged pipes made of different materials (steel, cast iron, ductile iron, asbestos cement, PVC). Available from DN 40 to DN 300. Also available in two-piece design.

FRIACLAMP repair clamps can be used with the standard NBR gasket for gas, water and wastewater.

Processing instructions

FRIACLAMP can be used to reliably seal damaged pipes. The installation length of the repair clamp should be selected so that it corresponds at least to the outside diameter of the pipe to be repaired.

The pipe surfaces must be prepared in accordance with the general installation requirements (see FRIACLAMP installation instructions).

* Permissible operating pressure:

Gas: Permitted operating pressure 5 bar (≤ DN 300).

Water: Permitted operating pressure:

≤ DN 200 PN 16

> DN 200 PN 10

> DN 300 on request.

Good reasons for FRIACLAMP

  • Quick locking System with Nuts and Bolts in V2A
  • No welded parts
  • Seal with large unique profile
  • Dovetail-shaped sealing webs form sealing lips when pressed against the pipe surface
  • Secure sealing even on corroded pipe surfaces
  • No sharp edges
  • No loose parts when opening the one-piece and two-piece repair clamps enable time-saving installation
  • Movable handle ensures easy installation with minimum installation space requirements
  • Optimized locking mechanism ensures defined pretensioning of each bolt
  • Assembly possible with standard tools