TA

T-Pieces with extra long outlet spigot

Straight connector with exposed heating coils for optimal heat transfer, large insertion depth, wide fusion zones plus cold zones at the end and in the middle to prevent the flow of molten material, for use without holding devices. Up to and including d63 extra long outlet spigot dimensioned for 2 fusion operations.

PE 100 SDR 11

Maximum working pressure 16 bar (water)/10 bar (gas)

Order ref. Design Article description Unit type w dd d1/DN d Thread Pipe d1 d2 Type DN R Rp Flansch_DN Flansch_PN Bereich einbaul RD_in_m Dimension Dimension Marking Ø Pipe Stock-
status
PU PU repair areaRepair areadR Lmin Lmax D d3 L Range of tolerance d/pipe L1 L1 LP t t1 t2 z z1 z2 z3 h h1 h2 d x s Bundled coil lengthwith safety Circuits Connections Manholeheight Manhole diameter WPconnecting pipe D1/D2 Operating pressurerange pmin - pmax VN b1 B dk di SDR SW1 SW2 Z durch_k s s1 s2 tmin tmax durchm_laenge A H1 H2 x y L2 H Holes
forscrew
D1 D2 D3 F b B1 B2 WSin mm Drilling
Ø da
e Turns
Open/close
Innen_Kugeldurchgang t1 min t1 max t2 min t2 max Weight
kg/each
Screws (pc. / size) Anzahl de Description Outlet dimension Basic size Reducer spherical shells Loaner c k l l1 l2 r Loop core diam. in mm E1 E a Artikelcode
616685 20/20 1 200 3200 29 77 95 31 45 8 17.00 42 0.040
616338 25/25 1 50 900 36 108 110 41 66 13 19.00 54 0.080
615719 32/32 1 35 630 44 116 131 39 80 19 22.00 61 0.120
615720 40/40 1 20 360 53 146 151 43 88 30 25.00 70 0.210
615721 50/50 1 10 180 67 175 186 49 110 38 29.00 80 0.360
615722 63/63 1 10 180 81 197 203 56 115 42 33.00 94 0.530
1 616677 90/90 1 12 96 116 280 219 79 79 61 43.00 126 1.250
2 616680 110/110 1 6 48 141 310 247 82 82 73 48.00 148 1.950
2 616684 160/160 1 3 24 203 390 326 98 98 97 45.00 205 4.950
1

Available in Q3/2020

2

Available in Q1/2020

FRIALEN safety fittings can be fused to pipes SDR11 - SDR 17.6. Minimum wall thickness s min ≥ 3 mm. Other SDR-stages on request. Please observe the marking directly at the product, which is mandatory. DVGW-Registration No.: DV-8601AU2248 and DV-8606AU2249.

Areas of Application

The FRIALEN-T pieces TA are used for pipe outlets of HD-PE pipelines.

Assembly Instructions

The fusion of the pipe ends with the FRIALEN-TA takes place by FRIALEN-fusing – leakproof and longitudinally strong.

The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).

Good reasons for using the FRIALEN-TA:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • At dim. up to d 63, Length of outlet spigot dimensioned for two fusion operations

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the fitting (Traceability-Coding)